Results From The WOW.Com Content Network
A drain-waste-vent system (or DWV) is the combination of pipes and plumbing fittings that captures sewage and greywater within a structure and routes it toward a water treatment system. It includes venting to the exterior environment to prevent a vacuum from forming and impeding fixtures such as sinks, showers, and toilets from draining freely ...
A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction. [1] Check valves are two-port valves, meaning they have two openings in the body, one for fluid to enter and the other for fluid to leave. There are various ...
A backflow prevention device is used to protect potable water supplies from contamination or pollution due to backflow. In water distribution systems, water is normally maintained at a significant pressure to enable water to flow from the tap, shower, or other fixture. Water pressure may fail or be reduced when a water main bursts, pipes freeze ...
Non-return or check valves allow the free flow of a fluid in one direction but prevent its flow in a reverse direction. They are often seen in drainage or sewage systems but may also be used in pressurized systems. Valves are available in several types, based on design and purpose: Gate, plug, or ball valves – Isolation; Globe valve ...
When they forced the resin out, a small amount of water forced its way past a stuck-open check valve and found its way into an instrument air line. This would eventually cause the feedwater pumps , condensate booster pumps, and condensate pumps to turn off around 4:00 a.m., which would, in turn, cause a turbine trip .
An air gap, as related to the plumbing trade, is the unobstructed vertical space between the water outlet and the flood level of a fixture. [1] Air gaps of appropriate design are legally required by water health and safety regulations in many countries. An air gap is the simplest form of a backflow prevention device.
Double check valve. A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. [1] It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air brake systems on heavy trucks which select from the highest ...
Water hammer. Effect of a pressure surge on a float gauge. Hydraulic shock (colloquial: water hammer; fluid hammer) is a pressure surge or wave caused when a fluid in motion is forced to stop or change direction suddenly: a momentum change. It is usually observed in a liquid but gases can also be affected.